APC Easy UPS 1000VA/700W Line Interactive Tower UPS
APC Easy UPS 1000VA/700W Line Interactive Tower UPS
SKU:UPAPC-SMV1000CAI
Couldn't load pickup availability
- See our return policy
- 24 months Manufacturer Warranty
Product Information
| Brand | APC |
|---|---|
| Category | UPS & Power Board |
| SKU | UPAPC-SMV1000CAI |
| Availability | In Stock |
Overview
- The APC Easy UPS 1000VA/700W is a single-phase line interactive UPS designed to protect critical business equipment from power interruptions and voltage fluctuations. With 1000VA capacity and 700W rated power, it delivers pure sine wave output to safely power computers, servers, networking equipment, and other sensitive devices.
The unit features automatic voltage regulation (AVR) to handle wide input voltage ranges (165–290V), making it ideal for Australian premises with inconsistent power conditions. Six IEC C13 outlets provide flexible connectivity for multiple devices, while the compact tower design fits easily into office and server environments.
Communication options include USB and RS-232 ports for system monitoring and management, plus an intelligent network card slot for integration with facility management systems. The lead-acid battery provides approximately 3 minutes 23 seconds of runtime at full 700W load, sufficient for graceful system shutdown or failover.
With a 24-month warranty and straightforward plug-and-play setup, the APC Easy UPS 1000VA/700W is a practical, cost-effective solution for businesses that need dependable power protection without complexity.
Specifications
| Rated Capacity | 1000 VA |
|---|---|
| Rated Power | 700 W |
| UPS Type | Line interactive |
| Waveform | Pure sine wave |
| Input Voltage | 220–240 V |
| Input Voltage Range | 165–290 V |
| Input Connection | IEC 60320 C14 |
| Input Frequency | 45–65 Hz (auto-sensing) |
| Output Voltage | 230 V |
| Output Frequency | 50/60 Hz ±1 Hz (unsynchronised) |
| Output Outlets | 6 × IEC 60320 C13 |
| Transfer Time | 2–6 ms typical; 12 ms maximum |
| Battery Type | Lead-acid battery |
| Runtime at Full Load | 3 minutes 23 seconds (700 W) |
| Load Range | 70–700 W |
| Crest Factor | 3:1 |
| Form Factor | Tower (not rack mountable) |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 0–95% (non-condensing) |
| Operating Altitude | 0–3000 m |
| Storage Temperature | −10–40 °C |
| Storage Humidity | 0–95% (non-condensing) |
| Storage Altitude | 0–15000 m |
| Acoustic Level | 45 dB(A) |
| IP Rating | IP20 |
| Communication Interfaces | USB, RS-232 |
| Network Card Slot | Yes (Intelligent Card Slot + Dry Contact) |
| Included Accessories | Documentation CD, user manual, USB cable |
| Replacement Battery | APC RBCV206 |
| Compatible Network Management Card | APV9602 |
| Warranty | 24 months |
Key Features
Ideal For
FAQs
How long will the APC Easy UPS 1000VA keep my equipment running during a power outage?
At full load (700W), the UPS provides approximately 3 minutes 23 seconds of backup runtime. Actual runtime depends on connected load; lighter loads will extend battery life. This duration is typically sufficient for graceful system shutdown or failover to alternative power.
Can I monitor the UPS remotely?
Yes. The UPS includes USB and RS-232 communication ports for monitoring and management via connected software. An optional intelligent network management card (APV9602) can be installed in the network card slot for extended remote monitoring and facility integration.
What is automatic voltage regulation (AVR) and why does it matter?
AVR automatically adjusts output voltage within safe operating ranges (165–290V input) without draining the battery, protecting equipment from voltage fluctuations common in unstable power environments. This extends battery life and improves equipment longevity.
Is the APC Easy UPS 1000VA suitable for server rooms?
Yes. The line interactive design, pure sine wave output, and network monitoring capabilities make it well-suited for small server rooms, network switches, and infrastructure protection. Multiple units can be deployed for redundancy if required.
What devices can I connect to the six IEC C13 outlets?
The six standard IEC C13 outlets support most office equipment: computers, monitors, network switches, printers, modems, routers, and point-of-sale systems. Ensure total connected load does not exceed 700W to maximise runtime.
Can I replace the battery myself?
The APC RBCV206 replacement battery is available separately. Battery replacement procedures are documented in the user manual. For safety and warranty compliance, installation by a qualified technician is recommended.
How quickly does the UPS switch to battery power during an outage?
Transfer time is 2–6 ms under typical conditions (12 ms maximum), which is fast enough to prevent most equipment loss. This brief switchover is imperceptible to computers and most office devices.
What is the warranty coverage?
The APC Easy UPS 1000VA includes a 24-month manufacturer warranty covering defects in materials and workmanship. Warranty terms and conditions are detailed in the documentation provided with the unit.
Share