APC Easy UPS SMV1500CAI 1500VA Line Interactive UPS
APC Easy UPS SMV1500CAI 1500VA Line Interactive UPS
SKU:UPAPC-SMV1500CAI
The APC Easy UPS SMV1500CAI is a 1500VA line interactive UPS tower designed for small to medium businesses. Featuring pure sine wave output, automatic voltage regulation, and six IEC C13 outlets, it delivers reliable power protection for workstations, servers, and critical equipment.
Couldn't load pickup availability
- See our return policy
- 24 months Manufacturer Warranty
Product Information
| Brand | APC |
|---|---|
| Category | UPS & Power Board |
| SKU | UPAPC-SMV1500CAI |
| Availability | In Stock |
Overview
- The APC Easy UPS SMV1500CAI is a single-phase line interactive UPS designed to protect essential business equipment from power outages and voltage fluctuations. With 1500VA capacity and 1050W rated output, it delivers pure sine wave power suitable for sensitive electronics including computers, servers, and retail terminals.
The tower-format design includes six IEC C13 outlets, allowing you to connect multiple devices simultaneously. Automatic voltage regulation (AVR) handles input voltage variations between 165V and 290V without consuming battery power, extending battery life during brown-outs and over-voltage conditions.
Built-in USB and RS-232 communication ports enable remote monitoring and management through compatible network cards. The intelligent card slot supports APC network management modules for enterprise-level oversight. At full 1050W load, the unit provides approximately 4 minutes of runtime, sufficient for graceful shutdown or power event management.
Ideally suited to small offices, retail environments, server rooms, and workstation clusters where reliable power protection is essential but rack mounting is not required.
Specifications
| Brand | APC |
|---|---|
| Model | SMV1500CAI |
| UPS Type | Line Interactive |
| Output Wave Form | Pure Sine Wave |
| Rated Capacity (VA) | 1500 VA |
| Rated Capacity (W) | 1050 W |
| Load Range | 105–1050 W |
| Runtime at Full Load | 4 minutes 8 seconds |
| Input Voltage (Nominal) | 230 V |
| Input Voltage Range | 220–240 V |
| Input Voltage Limits | 165–290 V |
| Input Connection Type | IEC 60320 C14 |
| Input Frequency | 45–65 Hz (auto-sensing) |
| Output Voltage (Nominal) | 230 V |
| Output Frequency | 50/60 Hz ±1 Hz (unsynchronised) |
| Number of Outlets | 6 |
| Outlet Type | IEC 60320 C13 |
| Transfer Time | 2–6 ms (typical), 12 ms (maximum) |
| Crest Factor | 3:1 |
| Battery Type | Lead-acid |
| Replacement Battery | APCRBCV207 |
| Network Management Compatible | APV9602 (Network Management Card) |
| Communication Interfaces | USB, RS-232 |
| Mounting | Tower (not rack-mountable) |
| Acoustic Level | 45 dBA |
| IP Rating | IP20 |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 0–95% (non-condensing) |
| Operating Altitude | 0–3000 m |
| Storage Temperature | -10–40 °C |
| Storage Humidity | 0–95% (non-condensing) |
| Storage Altitude | 0–15000 m |
| Warranty | 24 months |
Key Features
Ideal For
FAQs
How long will the APC SMV1500CAI run equipment during a power outage?
At full 1050W load, the UPS provides approximately 4 minutes 8 seconds of runtime. Actual runtime depends on the load connected. Lower loads will extend runtime; higher loads will reduce it. This timeframe is sufficient for system shutdown, data backup, or failover to alternative power.
What is the difference between line interactive and online UPS technology?
Line interactive UPS continuously monitors input voltage and switches to battery when voltage falls outside acceptable ranges. It's ideal for office and small business use. Online UPS converts all power through battery circuits, offering superior protection but at higher cost and power consumption. The SMV1500CAI's line interactive design suits general business needs cost-effectively.
Can I add network monitoring capabilities to this UPS?
Yes. The SMV1500CAI includes an Intelligent Card Slot that supports the APV9602 Network Management Card, enabling remote monitoring and management of the UPS via network connections.
What types of equipment can I safely connect to this UPS?
The pure sine wave output makes it suitable for computers, workstations, servers, point-of-sale systems, audio/video equipment, and other sensitive electronics. Each of the six IEC C13 outlets can support devices rated for the remaining capacity.
Is the SMV1500CAI suitable for server rooms?
Yes, it's ideal for small server rooms and office server environments. However, for larger data centres or mission-critical infrastructure, you may want to consider higher-capacity or redundant UPS configurations.
What happens if the input voltage is unstable or fluctuates?
The automatic voltage regulation (AVR) feature handles input voltage variations between 165–290V without consuming battery power. This protects equipment from damage while preserving battery life for genuine power outages.
When should I replace the battery?
Lead-acid batteries typically last 3–5 years depending on usage, temperature, and discharge cycles. APC recommends replacement batteries part number APCRBCV207. Battery replacement is a straightforward maintenance task.