APC NetShelter Metered Rack PDU 11kW 3-Phase 230V
APC NetShelter Metered Rack PDU 11kW 3-Phase 230V
SKU:UPA-AP8881
The APC NetShelter Metered Rack PDU is a 0U three-phase power distribution unit delivering 11kW at 230V. With 36 C13 and 6 C19 outlets, real-time metering, and remote monitoring capabilities, it provides precise power management and overload protection for data centre and server environments.
Couldn't load pickup availability
- See our return policy
- 24 months Manufacturer Warranty
Product Information
| Brand | APC |
|---|---|
| Category | Data Racks & Accessories |
| SKU | UPA-AP8881 |
| Availability | In Stock |
Overview
- The APC NetShelter AP8881 is a professional-grade metered rack PDU engineered for demanding data centre and server room environments. It delivers 11kW of three-phase power across 36 C13 and 6 C19 outlets, providing the outlet density and power capacity needed for modern IT infrastructure.
Built-in metering capabilities measure real-time volts, amps, real power and energy consumption, with an integral LCD display for local visibility. Remote monitoring via compatible sensors enables proactive management, user-defined alarms prevent accidental overloads, and historical data logging supports energy optimisation and chargeback accounting.
The 0U form factor integrates seamlessly into standard 19-inch racks without consuming rack space. With comprehensive safety certifications, robust construction, and a two-year warranty, the AP8881 is a reliable choice for organisations requiring resilient, monitored power distribution.
Specifications
| Brand | APC |
|---|---|
| Model | AP8881 |
| Product Type | Metered Rack PDU |
| Form Factor | 0U rackmount |
| Colour | Black |
| Input Configuration | 3-phase |
| Input Voltage | 400 V |
| Output Voltage | 230 V |
| Input Current | 16 A |
| Power Output | 11 kW |
| C13 Outlets | 36 |
| C19 Outlets | 6 |
| Total Outlets | 42 |
| Input Cord Type | IEC 309 3P+N+PE |
| Cord Length | 1.8 m |
| Number of Input Cables | 1 |
| Metering Capabilities | Volts, amps, real power (kW), energy (kWh) |
| Display | LCD |
| Monitoring | Real-time remote monitoring with user-defined alarms |
| Operating Temperature | -5 to 60 °C |
| Operating Humidity | 5 to 95 % |
| Operating Altitude | 0 to 10,000 ft |
| Storage Temperature | -25 to 65 °C |
| Storage Humidity | 5 to 95 % |
| Storage Altitude | 0 to 15,240 m |
| Safety Standards | CSA C22.2 No 60950, IEC 60950, UL 60950-1 |
| Product Certifications | VDE |
| Warranty Period | 24 months |
| Included Accessories | Installation guide, rack mounting brackets, serial configuration cable, safety guide |
| Compatible Mounting | AR7711 |
| Compatible Sensors | AP9335T, AP9335TH |
Key Features
Ideal For
FAQs
What is the difference between this metered PDU and a standard PDU?
The APC NetShelter AP8881 includes built-in metering to measure and log real-time power consumption (volts, amps, kW, kWh) at the PDU level. Standard PDUs provide power distribution only. Metering enables energy monitoring, overload prevention, customer chargeback, and capacity planning.
Can I monitor this PDU remotely?
Yes. The PDU features real-time remote monitoring capabilities when paired with compatible APC sensors (AP9335T or AP9335TH). This allows you to view power data, set alarms, and receive notifications from a management interface.
How many outlets does this PDU provide?
The AP8881 provides 42 total outlets: 36 C13 (standard 10A outlets for smaller devices) and 6 C19 (16A outlets for high-power equipment such as servers and PDUs).
What is the power capacity?
The PDU delivers 11kW of three-phase power at 230V with a 16A input current, suitable for medium to large server rooms and data centre environments.
Does this PDU consume rack space?
No. The AP8881 is a 0U (zero-U) form factor, meaning it mounts horizontally above or below rack units without consuming any standard 19-inch rack space.
What safety certifications does this PDU have?
The AP8881 meets CSA C22.2 No 60950, IEC 60950, UL 60950-1, and VDE safety standards, ensuring reliable operation in professional IT environments.
What is included in the box?
The PDU includes an installation guide, rack mounting brackets, serial configuration cable, and safety guide. A 1.8 m IEC 309 3P+N+PE input cord is also provided.
What warranty is provided?
The APC NetShelter AP8881 includes a 24-month manufacturer warranty covering defects in materials and workmanship.