APC Netshelter Metered Rack PDU 0U 32A 230V

APC Netshelter Metered Rack PDU 0U 32A 230V

SKU:UPA-AP8853X678

The APC Netshelter Metered Rack PDU is a 0U power distribution unit designed for data centre environments. Featuring real-time power monitoring, 42 total outlets (36× C13, 6× C19), and user-defined alarm thresholds, it delivers precise energy management and circuit protection ...
Regular price $2,087.25 AUD
Regular price Sale price $2,087.25 AUD
Sale Sold out
Taxes included. Shipping calculated at checkout.
Quantity
No reviews yet

Product Information

BrandAPC
CategoryData Racks & Accessories
SKUUPA-AP8853X678
AvailabilityOut of Stock
APC Netshelter Metered Rack PDU 0U 32A 230V$2,087.25
$2,087.25
Overview
  • The APC Netshelter Metered Rack PDU delivers professional-grade power distribution and monitoring for modern data centres. With 42 strategically arranged outlets (36× C13 and 6× C19), it accommodates diverse IT equipment while its 0U profile maximises available rack space.

    Real-time power metering enables data centre managers to monitor consumption, set custom alarm thresholds, and receive alerts before circuit overloads occur. The integrated temperature and humidity sensor port provides environmental visibility, supporting comprehensive facility management.

    Management flexibility is built in via secure Web, SNMP, and Telnet interfaces, with integration into APC's StruxureWare centralised management platform for enterprise-scale deployments. Ultra-low profile circuit breakers and locking IEC receptacles ensure reliable, protected power delivery across your infrastructure.
Specifications
BrandAPC
ModelAP8853X678
PDU TypeMetered
Form Factor0U (Zero Rack Units)
Input Voltage230V
Input Connector TypeClipsal 56 Series AS/NZ 32A
Input Current Rating32A
Output Voltage230V
Number of C13 Outlets36
Number of C19 Outlets6
Total Outlets42
Power Socket StandardIEC 60320
Cable Length3.0 m
Number of Input Cables1
Network Frequency50/60 Hz
Permissible Voltage Range220–240V
Operating Temperature−5 to 45 °C
Operating Humidity5 to 95% RH
Operating Altitude0 to 10,000 ft
Storage Temperature−25 to 65 °C
Storage Humidity5 to 95% RH
Storage Altitude0 to 15,240 m
CertificationsVDE
Included AccessoriesInstallation guide, rack mounting brackets, serial configuration cable
Environmental MonitoringTemperature and humidity sensor port
Management InterfacesWeb, SNMP, Telnet
Warranty24 months
Key Features
42 total outlets: 36× IEC C13 and 6× IEC C19 connectors
Real-time power metering for accurate energy monitoring
0U form factor for space-efficient rack installation
User-defined alarm thresholds with local and remote alerts
Temperature and humidity sensor port for environmental monitoring
Secure Web, SNMP, and Telnet management interfaces
Ultra-low profile circuit breakers for enhanced protection
32A input current with 230V main output
Ideal For
Data centre power distribution and load balancing
IT environments requiring real-time energy optimisation
Facilities needing remote circuit monitoring and alerts
Organisations implementing StruxureWare management platforms
High-density rack deployments with multiple device types
FAQs
What does a metered PDU do?

A metered PDU monitors real-time power consumption and provides detailed utilisation data. This allows data centre managers to track circuit loads, balance equipment distribution, and receive alerts if thresholds are exceeded, helping prevent overloads and optimise energy efficiency.

Can I monitor this PDU remotely?

Yes. The APC Netshelter PDU supports secure Web, SNMP, and Telnet interfaces for remote monitoring and configuration. It also integrates with APC's StruxureWare centralised management platform for enterprise deployments.

What's the difference between C13 and C19 outlets?

C13 outlets are standard, lower-power connectors suited for PCs, monitors, and general equipment. C19 outlets are higher-capacity connectors designed for servers and power-hungry devices. This PDU includes both to accommodate diverse IT equipment types.

Is this unit rack-mountable?

The PDU itself is a 0U (Zero U) unit, meaning it doesn't occupy standard vertical rack space. However, it requires external mounting brackets (included) for secure installation within your rack infrastructure.

What input voltage and plug type does it require?

The unit requires 230V input via a Clipsal 56 Series AS/NZ 32A plug, which is the Australian/New Zealand standard. It supports the permissible voltage range of 220–240V.

Does it include environmental monitoring?

Yes. The PDU features a dedicated temperature and humidity sensor port, allowing facility managers to monitor environmental conditions alongside power metrics for comprehensive data centre oversight.

What's included in the box?

The PDU includes an installation guide, rack mounting brackets, and a serial configuration cable for setup and management.

What warranty is provided?

The APC Netshelter Metered Rack PDU includes a 24-month manufacturer's warranty.