APC NetShelter Metered Rack PDU 0U 230V 16A
APC NetShelter Metered Rack PDU 0U 230V 16A
SKU:UPAPCAP8858
The APC NetShelter Metered Rack PDU is a 0U power distribution unit designed for data centres and server rooms. Featuring real-time metering, LCD display, and remote monitoring capabilities, it delivers precise power management and circuit overload protection for critical infrastructure.
Couldn't load pickup availability
- See our return policy
- 24 months Manufacturer Warranty
Product Information
| Brand | APC |
|---|---|
| Category | Data Racks & Accessories |
| SKU | UPAPCAP8858 |
| Availability | Out of Stock |
Overview
- The APC NetShelter Metered Rack PDU AP8858 is a professional-grade power distribution solution for data centres and server environments. It provides comprehensive power metering and monitoring capabilities, allowing IT teams to track real-time consumption across 20 outlets (18x C13 and 2x C19) while maintaining detailed historical records for billing and capacity planning.
The unit's LCD display provides local visibility of critical power metrics including volts, amps, real power draw (kW) and cumulative energy usage (kWh). User-defined alarms prevent circuit overloads that could cause unplanned downtime to critical equipment. Remote monitoring via EcoStruxure IT enables centralised management, with support for daisy-chaining up to 4 PDUs from a single IP address, simplifying deployment across larger installations.
As a zero-rack-unit (0U) design, it integrates seamlessly into existing infrastructure without consuming valuable rack space. The metered PDU supports both 208V and 230V inputs at 16A, delivering 3.3 kW or 3.7 kW respectively, making it suitable for diverse international and Australian electrical standards.
Specifications
| Brand | APC |
|---|---|
| Model | AP8858 |
| Product Type | Metered Rack PDU |
| Rack Units | 0U |
| Mounting Mode | Vertical rack mounted |
| Input Voltage Options | 208V or 230V |
| Input Rated Current | 16A |
| Input Connector | IEC 60320 C20 |
| Load Capacity | 3300 VA at 230V / 3300 VA at 208V |
| C13 Outlets | 18 |
| C19 Outlets | 2 |
| Total Outlets | 20 |
| Output Voltage Support | 100V, 200V, 208V, 230V |
| Network Frequency | 50/60 Hz |
| Operating Temperature | -5 to +60°C |
| Operating Humidity | 5 to 95% (non-condensing) |
| Operating Altitude | 0 to 10,000 feet |
| Storage Temperature | -25 to +65°C |
| Storage Humidity | 5 to 95% (non-condensing) |
| Storage Altitude | 0 to 15,240 metres |
| Display | LCD display |
| Metering Capability | Volts, amps, real power (kW), energy (kWh) |
| Remote Monitoring | EcoStruxure IT integration |
| Daisy-Chain Support | Up to 4 PDUs from single IP address |
| USB Port | Local firmware updates |
| Colour | Black |
| Certifications | METI Denan, VDE |
| Standards Compliance | CSA C22.2 No 60950, IEC 60950, UL 60950-1 |
| Warranty | 24 months |
| Included Accessories | Installation guide, rack mounting brackets, serial configuration cable, safety guide |
Key Features
Ideal For
FAQs
What does a metered PDU do?
A metered PDU measures and displays real-time power consumption (volts, amps, kW, and kWh) for each outlet or group of outlets. This enables accurate tracking of power usage, cost allocation to different departments or customers, and helps prevent circuit overloads that could cause downtime.
Can I monitor this PDU remotely?
Yes. The AP8858 integrates with APC's EcoStruxure IT platform for remote monitoring and management. You can also daisy-chain up to 4 PDUs and monitor them all from a single IP address. For local management, the LCD display provides immediate visibility of power metrics.
How many outlets does this PDU have?
The AP8858 provides 20 total outlets: 18x IEC 60320 C13 outlets (for standard server and equipment power cords) and 2x IEC 60320 C19 outlets (for high-power devices).
What input voltage does this PDU require?
The AP8858 supports both 208V and 230V single-phase input at 16A. At 230V, it delivers 3.7 kW; at 208V, it delivers 3.3 kW. It can also accept input from 100–240V permissible range.
Does this PDU take up rack space?
No. This is a 0U (zero-rack-unit) design, meaning it mounts vertically on the side or rear of a rack without consuming any standard 1U, 2U, or 3U rack space.
What alarms and protection does it offer?
The AP8858 includes user-defined alarms that alert you to potential circuit overloads before they occur. This helps prevent accidental power loss to critical equipment and enables proactive capacity management.
Is this PDU suitable for Australian data centres?
Yes. The AP8858 supports 230V input, which is standard in Australia. It complies with relevant international standards (IEC 60950, UL 60950-1, CSA C22.2) and can operate reliably in typical Australian server room and data centre environments.
What warranty does this PDU come with?
The AP8858 includes a 24-month manufacturer warranty covering defects in materials and workmanship.