APC NetShelter Metered Rack PDU 0U 230V 16A

APC NetShelter Metered Rack PDU 0U 230V 16A

SKU:UPAPCAP8858

The APC NetShelter Metered Rack PDU is a 0U power distribution unit designed for data centres and server rooms. Featuring real-time metering, LCD display, and remote monitoring capabilities, it delivers precise power management and circuit overload protection for critical infr...
Regular price $1,350.25 AUD
Regular price Sale price $1,350.25 AUD
Sale Sold out
Taxes included. Shipping calculated at checkout.
Quantity
No reviews yet

Product Information

BrandAPC
CategoryData Racks & Accessories
SKUUPAPCAP8858
AvailabilityOut of Stock
APC NetShelter Metered Rack PDU 0U 230V 16A$1,350.25
$1,350.25
Overview
  • The APC NetShelter Metered Rack PDU AP8858 is a professional-grade power distribution solution for data centres and server environments. It provides comprehensive power metering and monitoring capabilities, allowing IT teams to track real-time consumption across 20 outlets (18x C13 and 2x C19) while maintaining detailed historical records for billing and capacity planning.

    The unit's LCD display provides local visibility of critical power metrics including volts, amps, real power draw (kW) and cumulative energy usage (kWh). User-defined alarms prevent circuit overloads that could cause unplanned downtime to critical equipment. Remote monitoring via EcoStruxure IT enables centralised management, with support for daisy-chaining up to 4 PDUs from a single IP address, simplifying deployment across larger installations.

    As a zero-rack-unit (0U) design, it integrates seamlessly into existing infrastructure without consuming valuable rack space. The metered PDU supports both 208V and 230V inputs at 16A, delivering 3.3 kW or 3.7 kW respectively, making it suitable for diverse international and Australian electrical standards.
Specifications
BrandAPC
ModelAP8858
Product TypeMetered Rack PDU
Rack Units0U
Mounting ModeVertical rack mounted
Input Voltage Options208V or 230V
Input Rated Current16A
Input ConnectorIEC 60320 C20
Load Capacity3300 VA at 230V / 3300 VA at 208V
C13 Outlets18
C19 Outlets2
Total Outlets20
Output Voltage Support100V, 200V, 208V, 230V
Network Frequency50/60 Hz
Operating Temperature-5 to +60°C
Operating Humidity5 to 95% (non-condensing)
Operating Altitude0 to 10,000 feet
Storage Temperature-25 to +65°C
Storage Humidity5 to 95% (non-condensing)
Storage Altitude0 to 15,240 metres
DisplayLCD display
Metering CapabilityVolts, amps, real power (kW), energy (kWh)
Remote MonitoringEcoStruxure IT integration
Daisy-Chain SupportUp to 4 PDUs from single IP address
USB PortLocal firmware updates
ColourBlack
CertificationsMETI Denan, VDE
Standards ComplianceCSA C22.2 No 60950, IEC 60950, UL 60950-1
Warranty24 months
Included AccessoriesInstallation guide, rack mounting brackets, serial configuration cable, safety guide
Key Features
Real-time metering of volts, amps, real power (kW) and energy (kWh)
20 total outlets: 18x IEC C13 and 2x IEC C19
LCD display for local monitoring and user-defined alarms
Remote monitoring and management via EcoStruxure IT integration
Daisy-chain up to 4 PDUs from a single IP address
3.7 kW capacity at 230V 16A input
Zero-rack-unit (0U) vertical mounting design
24-month manufacturer warranty
Ideal For
Data centres requiring detailed power consumption tracking and cost allocation
Server rooms needing circuit overload prevention and real-time alerts
IT infrastructure environments with multiple PDU management requirements
Facilities planning capacity expansion and optimising energy usage
Organisations implementing EcoStruxure IT monitoring systems
FAQs
What does a metered PDU do?

A metered PDU measures and displays real-time power consumption (volts, amps, kW, and kWh) for each outlet or group of outlets. This enables accurate tracking of power usage, cost allocation to different departments or customers, and helps prevent circuit overloads that could cause downtime.

Can I monitor this PDU remotely?

Yes. The AP8858 integrates with APC's EcoStruxure IT platform for remote monitoring and management. You can also daisy-chain up to 4 PDUs and monitor them all from a single IP address. For local management, the LCD display provides immediate visibility of power metrics.

How many outlets does this PDU have?

The AP8858 provides 20 total outlets: 18x IEC 60320 C13 outlets (for standard server and equipment power cords) and 2x IEC 60320 C19 outlets (for high-power devices).

What input voltage does this PDU require?

The AP8858 supports both 208V and 230V single-phase input at 16A. At 230V, it delivers 3.7 kW; at 208V, it delivers 3.3 kW. It can also accept input from 100–240V permissible range.

Does this PDU take up rack space?

No. This is a 0U (zero-rack-unit) design, meaning it mounts vertically on the side or rear of a rack without consuming any standard 1U, 2U, or 3U rack space.

What alarms and protection does it offer?

The AP8858 includes user-defined alarms that alert you to potential circuit overloads before they occur. This helps prevent accidental power loss to critical equipment and enables proactive capacity management.

Is this PDU suitable for Australian data centres?

Yes. The AP8858 supports 230V input, which is standard in Australia. It complies with relevant international standards (IEC 60950, UL 60950-1, CSA C22.2) and can operate reliably in typical Australian server room and data centre environments.

What warranty does this PDU come with?

The AP8858 includes a 24-month manufacturer warranty covering defects in materials and workmanship.