APC Netshelter Metered Rack PDU 0U 230V 24A
APC Netshelter Metered Rack PDU 0U 230V 24A
SKU:UPAPC-AP8886
The APC Netshelter Metered Rack PDU is a 0U power distribution unit designed for data centre environments. Featuring 42 total outlets (30x C13, 12x C19), real-time metering, and remote monitoring capabilities, it delivers precise power management and energy optimisation for IT infrastructure.
Couldn't load pickup availability
- See our return policy
- 24 months Manufacturer Warranty
Product Information
| Brand | APC |
|---|---|
| Category | Data Racks & Accessories |
| SKU | UPAPC-AP8886 |
| Availability | In Stock |
Overview
- The APC Netshelter Metered Rack PDU (AP8886) is a professional-grade power distribution solution engineered for modern data centre operations. With 42 total outlets and comprehensive metering capabilities, it enables IT managers to monitor real-time power consumption, identify load imbalances, and optimise facility efficiency.
Designed for vertical rack mounting in a space-saving 0U configuration, this PDU combines robust power delivery with intelligent monitoring. The integrated temperature and humidity sensor port provides additional environmental visibility, supporting better decision-making for cooling and capacity planning.
Integration with APC's InfraStruxure Central management suite allows centralised monitoring across multiple PDUs and data centre systems. User-defined alarms alert operations teams to potential overloads before issues occur, reducing downtime risk and supporting predictable total cost of ownership.
With full compliance to international standards and secure management interfaces, the AP8886 is ideal for organisations seeking granular power visibility without sacrificing reliability or ease of deployment.
Specifications
| Brand | APC |
|---|---|
| Model | AP8886 |
| Product Type | Metered Rack PDU |
| Form Factor | 0U |
| Mounting | Vertical rack mounted |
| Input Voltage | 400V 3-phase |
| Input Current | 32A maximum |
| Output Voltage | 230V |
| Load Capacity | 22,000 VA (22 kW) |
| Network Frequency | 50/60 Hz |
| C13 Outlets | 30 |
| C19 Outlets | 12 |
| Total Outlets | 42 |
| Power Cord Length | 1.83 m |
| Connector Type | IEC 309 3P+N+PE |
| Metering Type | Real power metering |
| Monitoring Interfaces | Web, SNMP, Telnet |
| Sensor Port | Temperature and humidity sensor compatible |
| Circuit Protection | Ultra-low profile circuit breakers |
| Receptacles | Locking IEC |
| Colour | Black |
| Operating Temperature | -5°C to 60°C |
| Operating Humidity | 5% to 95% relative humidity |
| Operating Altitude | 0 to 10,000 ft |
| Storage Temperature | -25°C to 65°C |
| Storage Humidity | 5% to 95% relative humidity |
| Storage Altitude | 0 to 15,240 m |
| Certifications | VCCI Class A, VDE, EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC Part 15 Class A, ICES-003 |
| Warranty | 24 months |
| Included Accessories | Installation guide, rack mounting brackets, serial configuration cable, safety guide |
Key Features
Ideal For
FAQs
What is the difference between C13 and C19 outlets on this PDU?
C13 outlets are standard IEC connectors for most servers, workstations, and networking equipment. C19 outlets are heavier-duty connectors designed for high-power devices such as servers, storage arrays, and large UPS units. This PDU provides both types to support mixed power requirements in data centre environments.
Can I monitor power usage remotely with this PDU?
Yes. The AP8886 features real-time metering accessible via Web, SNMP, or Telnet interfaces. You can monitor power consumption, receive alerts for overload conditions, and integrate it with APC's InfraStruxure Central management platform for centralised monitoring across multiple PDUs.
What does 0U mean, and why is it important?
0U means the PDU does not consume any rack units of vertical space. It mounts inline with the power cord, allowing you to maximise usable rack space for servers and network equipment while still providing complete power distribution and monitoring.
What is the maximum power load this PDU can handle?
The AP8886 supports a maximum load capacity of 22,000 VA (22 kW) at 230V output with a 32A input current. You can set user-defined alarm thresholds to alert you before reaching capacity limits, preventing overloads and downtime.
Is this PDU suitable for international use?
The AP8886 is configured for 230V 3-phase input and operates at 50/60 Hz, making it suitable for Australia and compatible regions. Input/output voltage and frequency should be verified for your specific location before deployment.
What sensors can be connected to this PDU?
The AP8886 features a temperature and humidity sensor port compatible with APC sensors such as the AP9335T and AP9335TH, enabling environmental monitoring alongside power metrics for comprehensive data centre oversight.
How is the AP8886 mounted in a rack?
The PDU mounts vertically with a 0U footprint using the included rack mounting brackets. The 1.83 m power cord connects to the rack's IEC 309 3P+N+PE input, with outlets facing outward for easy equipment connection.
What management platforms are compatible with this PDU?
The AP8886 integrates with APC InfraStruxure Central, InfraStruxure Operations, InfraStruxure Capacity, and InfraStruxure Energy Efficiency platforms, enabling centralised power, environmental, and capacity management across your data centre infrastructure.