APC Easy UPS SRV2KI 2000VA Online UPS Tower
APC Easy UPS SRV2KI 2000VA Online UPS Tower
SKU:UPAPC-SRV2KI
The APC Easy UPS SRV2KI is a 2000VA/1600W double-conversion online UPS designed for IT professionals managing critical business systems. Featuring pure sine wave output, automatic bypass protection, and intelligent management capabilities, it ensures uninterrupted power for network equipment and servers.
Couldn't load pickup availability
- See our return policy
- 24 months Manufacturer Warranty
Product Information
| Brand | APC |
|---|---|
| Category | UPS & Power Board |
| SKU | UPAPC-SRV2KI |
| Availability | In Stock |
Overview
- The APC Easy UPS SRV2KI is a professional-grade 2000VA online UPS designed to protect critical business systems from power interruptions. Using double-conversion technology, it continuously converts incoming AC power to DC and back to pure sine wave AC, ensuring clean, stable power to sensitive electronics at all times.
The unit features four IEC C13 outlets and an intelligent card slot, enabling integration with EcoStruxure IT and other centralised management platforms for remote monitoring and control. Built-in automatic and manual bypass protection guarantees uninterrupted power delivery even during internal faults, making it ideal for environments where downtime is not an option.
With a 4-minute runtime at full load and wide input voltage tolerance (110-285V), the SRV2KI adapts to Australian power conditions and provides sufficient time for graceful system shutdown or load transfer. The tower design fits easily into server rooms and network closets, while the 50 dB acoustic level keeps noise levels manageable in office environments.
Specifications
| Power Rating | 2000VA / 1600W |
|---|---|
| UPS Type | Double-conversion online |
| Form Factor | Tower |
| Input Voltage | 230V standard (220-240V supported) |
| Input Frequency | 40-70 Hz auto-sensing |
| Input Connection | IEC 60320 C14 |
| Output Voltage | 230V standard (220-240V supported) |
| Output Outlets | 4x IEC 60320 C13 |
| Cable Included | 1.50m (1 IEC C13 to Schuko, 1 IEC C13 to C14, 1 USB, 1 RS-232) |
| Input Voltage Range (Half Load) | 160-1600W |
| Input Voltage Limits | 110-285V (half load), 160-280V (full load) |
| Runtime at Full Load | 4 minutes 2 seconds |
| Battery Type | Lead-acid |
| Replacement Battery | APCRBCV204 |
| Operating Temperature | 0-40°C |
| Storage Temperature | -20-50°C |
| Relative Humidity | 0-95% non-condensing |
| Operating Altitude | 0-3000m |
| Storage Altitude | 0-15000m |
| Acoustic Level | 50 dBA |
| Heat Dissipation | 745 BTU/h |
| IP Rating | IP20 |
| Mounting | Tower (not rack-mountable) |
| Management Interface | LCD display, Intelligent Card Slot |
| Compatible Management Cards | AP9544, SRVSMB001, VGL9901I |
| Warranty | 24 months |
Key Features
Ideal For
FAQs
How long will the APC SRV2KI keep my equipment running during a power cut?
At full load (1600W), the SRV2KI provides approximately 4 minutes 2 seconds of runtime. This is sufficient time to shut down systems gracefully, transfer loads, or activate alternative power sources. Runtime extends significantly at reduced loads.
What is the difference between online and offline UPS?
The APC SRV2KI uses double-conversion online technology, which continuously converts power from AC to DC to AC. This provides superior protection with pure sine wave output and zero transfer time, making it ideal for sensitive equipment like servers and network infrastructure.
Can the SRV2KI be remotely monitored and managed?
Yes. The SRV2KI features an Intelligent Card Slot that supports management cards like the AP9544, enabling integration with EcoStruxure IT and third-party centralised management platforms for remote monitoring, alerts, and shutdown automation.
How many devices can I connect to the SRV2KI?
The SRV2KI has 4x IEC C13 outlets. You can connect multiple devices to each outlet using appropriately rated power distribution blocks, but total power draw must not exceed 1600W.
Will the SRV2KI work with Australian power standards?
Yes. The SRV2KI accepts 230V input (220-240V range supported) and auto-senses network frequency from 40-70 Hz. It's compatible with Australian mains power and includes an IEC C13 to Schuko cable for standard Australian power outlets.
What happens if the UPS detects an internal fault?
The SRV2KI includes both automatic and manual bypass protection. If an internal fault is detected, the bypass automatically routes power directly to the load, ensuring uninterrupted supply while the fault is resolved.
How do I replace the battery?
The SRV2KI uses lead-acid batteries. The replacement battery model is APCRBCV204. Battery replacement should be performed by qualified technicians to ensure safety and proper installation.
Is the SRV2KI rack-mountable?
No. The SRV2KI has a tower form factor and is not rack-mountable. It's designed for placement on the floor or on shelving in server rooms, network closets, or equipment rooms.