APC AP7552 Rack PDU Basic 16A 230V
APC AP7552 Rack PDU Basic 16A 230V
SKU:UPA-AP7552
Couldn't load pickup availability
- See our return policy
- 24 months Manufacturer Warranty
Product Information
| Brand | APC |
|---|---|
| Category | Data Racks & Accessories |
| SKU | UPA-AP7552 |
| Availability | In Stock |
Overview
- The APC AP7552 is a space-saving basic rack PDU engineered for data centre and server room applications. Its zero U mounting design allows installation alongside active equipment without consuming valuable rack space, making it ideal for high-density server deployments.
With 20 C13 outlets and 4 C19 connectors, the PDU accommodates a wide range of IT equipment including servers, switches, and power-hungry devices. The 16A input current and 3680 VA capacity provide sufficient power distribution for small to medium-sized rack configurations.
Deployed as part of larger power management infrastructure, the AP7552 integrates seamlessly with compatible APC accessories and monitoring systems. Its straightforward design prioritises reliability and ease of installation, with toolless mounting brackets and a comprehensive 24-month warranty.
Specifications
| Brand | APC |
|---|---|
| Model | AP7552 |
| Product Type | Basic Rack PDU |
| Mounting | Zero U vertical rack mount |
| Input Voltage | 200 V, 208 V, 230 V |
| Output Voltage | 230 V |
| Input Current | 16 A |
| Load Capacity | 3680 VA |
| Input Connector | IEC 60320 C20 |
| C13 Outlets | 20 |
| C19 Outlets | 4 |
| Power Cord Length | 3.05 m |
| Network Frequency | 50/60 Hz |
| Operating Temperature | 0 to 45 °C |
| Operating Humidity | 5 to 95% relative humidity |
| Operating Altitude | 0 to 10,000 feet |
| Storage Temperature | -25 to 65 °C |
| Storage Humidity | 5 to 95% relative humidity |
| Storage Altitude | 0 to 15,240 metres |
| Colour | Black |
| Included Accessories | Installation guide, rack mounting brackets, toolless mounting kit |
| Warranty | 24 months |
Key Features
Ideal For
FAQs
What is zero U mounting and why does it matter?
Zero U mounting means the PDU occupies no rack units of vertical space. It mounts horizontally at the front or rear of the rack, allowing you to maximise usable rack space for active equipment like servers and switches—critical in high-density data centre environments.
Can the APC AP7552 be used internationally?
Yes. The PDU accepts input voltages of 200 V, 208 V, and 230 V, and operates on both 50 Hz and 60 Hz power frequencies, making it suitable for deployment across most regions globally.
What is the difference between C13 and C19 outlets?
C13 outlets are standard connections for most IT equipment (servers, switches, monitors). C19 outlets are heavier-duty connectors designed for high-power devices. This PDU provides both for flexibility across different infrastructure needs.
What is the maximum power load this PDU can handle?
The APC AP7552 is rated for 3680 VA at 16A input current, making it suitable for small to medium-sized rack configurations with multiple standard IT devices.
Is this PDU compatible with APC monitoring and management systems?
The AP7552 is a basic PDU without built-in network connectivity. It is designed for straightforward power distribution. For advanced monitoring, consider higher-tier APC PDU models with intelligent features.
What mounting hardware is included?
The PDU ships with an installation guide, rack mounting brackets, and a toolless mounting kit, allowing rapid deployment without specialised tools.
What warranty does the APC AP7552 include?
APC provides a 24-month manufacturer warranty covering defects in materials and workmanship.