APC Rack PDU 9000 Switched 32A 230V ZeroU

APC Rack PDU 9000 Switched 32A 230V ZeroU

SKU:UPAPC-APDU9953

The APC Rack PDU 9000 Switched is a zero-space rack power distribution unit designed for data centre and server room environments. Featuring 24 outlets (21 C13 and 3 C19), switched outlet control, and SNMP/Redfish management, it delivers reliable power distribution and remote ...
Regular price $2,821.50 AUD
Regular price Sale price $2,821.50 AUD
Sale Sold out
Taxes included. Shipping calculated at checkout.
Quantity
No reviews yet

Product Information

BrandAPC
CategoryData Racks & Accessories
SKUUPAPC-APDU9953
AvailabilityOut of Stock
APC Rack PDU 9000 Switched 32A 230V ZeroU$2,821.50
$2,821.50
Overview
  • The APC Rack PDU 9000 Switched is a professional-grade power distribution unit designed for mission-critical data centre and server room applications. Its ZeroU form factor allows installation above or below existing rack equipment without consuming valuable rack space, making it ideal for space-constrained environments.

    With 24 individually switchable outlets—comprising 21 C13 and 3 C19 connectors—the PDU accommodates a wide range of equipment from standard servers to high-power devices. The 32A 230V input and 7400 VA load capacity provide substantial power handling for medium to large rack deployments.

    Network management is seamless through SNMP and Redfish protocol support, enabling remote power cycling, outlet monitoring, and integration with existing data centre management systems via 10/100/1000BASE-T connectivity. The unit operates reliably across a wide temperature and humidity range, with support for 50/60 Hz mains frequencies suitable for global data centre standards.

    Included installation brackets and comprehensive documentation simplify deployment, whilst the 36-month warranty provides long-term peace of mind for critical infrastructure investments.
Specifications
ColourBlack
PDU TypeSwitched
Rack Units0U (ZeroU)
Total Outlets24 (21 × C13, 3 × C19)
Input Voltage Range200–240V
Rated Input Current32A
Load Capacity7400 VA
Network Frequency50/60 Hz
Mounting PositionVertical
Cord Length3.05 m
Input Cables1
Communication ProtocolsSNMP, Redfish
Network Interface10/100/1000BASE-T
Operating Temperature−5 to +60 °C
Operating Humidity5–95% (non-condensing)
Operating Altitude0–10,000 ft
Storage Temperature−25 to +65 °C
Storage Humidity5–95% (non-condensing)
Storage Altitude0–15,240 m
Included AccessoriesInstallation guide, mounting brackets, safety guide
Warranty36 months
Key Features
24 switched outlets (21 C13 and 3 C19) for flexible equipment connections
32A 230V input with 7400 VA load capacity
Zero-space (ZeroU) design fits above or below rack equipment without consuming rack units
SNMP and Redfish protocol support for remote power management and monitoring
Integrated 10/100/1000BASE-T network connectivity for centralised control
Wide input voltage range (200–240V) for operational stability
36-month manufacturer warranty
Includes mounting brackets and comprehensive installation guides
Ideal For
Data centres requiring individual outlet-level power control and monitoring
Server rooms with space constraints and need for ZeroU PDU solutions
IT environments using SNMP or Redfish-based power management systems
Enterprise infrastructure needing redundant power distribution with remote access
Multi-equipment racks requiring separate circuit management
FAQs
What does ZeroU mean, and why is it important?

ZeroU means the PDU consumes zero rack units of space. It mounts vertically above or below existing rack equipment, maximising usable rack space for servers and other infrastructure without requiring dedicated rack height.

Can I remotely control individual outlets?

Yes. The APC Rack PDU 9000 Switched supports SNMP and Redfish protocols, allowing remote power cycling and monitoring of individual outlets via network management systems and IPMI-compatible tools.

What is the maximum load capacity?

The PDU has a maximum load capacity of 7400 VA at 32A input current on 230V mains. Always verify connected equipment power consumption does not exceed this limit.

Is this PDU suitable for 415V three-phase systems?

No. This PDU is designed for single-phase 200–240V input. For three-phase or higher voltage requirements, consult the APC product range for suitable alternatives.

What network protocols does this PDU support?

The PDU supports SNMP (Simple Network Management Protocol) and Redfish protocol over 10/100/1000BASE-T Ethernet, enabling integration with enterprise data centre management platforms.

What is included in the box?

The package includes the PDU unit, installation guide, rack mounting brackets, and safety guide. A 3.05 m power cord is also provided.

What is the warranty period?

The APC Rack PDU 9000 Switched comes with a 36-month manufacturer warranty covering defects in materials and workmanship.

Can this PDU work in hot or cold environments?

Yes. The PDU operates reliably in ambient temperatures from −5 to +60 °C and can be stored in temperatures from −25 to +65 °C, making it suitable for various data centre climates.